   Accessing the Gocator GUI behind a router

Question 

Can the Gocator GUI be accessed behind a router?

Answer 

Sensor Model All
Firmware Version 3.x, 4.x
SDK Version n/a

Yes, the Gocator GUI can be accessed behind a router with the following ports forwarded:

  • 80 - HTTP
  • 843 - Adobe Flash security socket
  • 3190 - Control channel port
  • 3192 - Upgrade port
  • 3194 - Health channel port
  • 3195 - Private diagnostic data port
  • 3196 - Public data port

NOTE: This is for accessing the GUI only. For Gocator-to-Gocator and SDK-to-Gocator communication, an unmanaged network switch is required.