   Difference between using a flat surface and a bar for alignment when using a single sensor

Question 

What is the difference between using a flat surface and a bar for alignment when using a single sensor?

Answer 

Sensor Model All
Firmware Version 3.x, 4.x
SDK Version n/a

When using a single sensor, a bar with one hole will also center the profile along the X=0, whereas a flat surface will only correct the angle.