Question 

How can I save the current Gocator configuration through the SDK?

Answer 

Sensor Model All
Firmware Version 3.x, 4.x
SDK Version 3.x, 4.x

Gocator firmware 3.x

In Gocator 3.x, the current configuration is stored in the hidden file _live.cfg. To permanently store this configuration using the SDK, this file can be copied using the Go2System_CopyFile() function.

Gocator firmware 4.x

In Gocator 4.x, the current configuration is stored in the hidden file _live.job. To permanently store this configuration using the SDK, this file can be copied using the GoSensor_CopyFile() function.